Til toppen

FRENIC Ace

FRENIC Ace fra Fuji Electric

Product Information

Customizabel logic

Customizable logic function is available as a standard feature. FRENIC-Ace has built-in customizable logic functions with a maximum of 200 steps including both digital and analog operation functions, giving customers the ability to customize their inverters—from simple logic functions to full-scale programming. Fuji Electric also has plans to offer programming templates for wire drawing machines, hoists, spinning machines, and other applications so that the FRENIC-Ace can be used as a dedicated purpose inverter.

Superior Flexibility

FRENIC-Ace has readily available interface cards and various types of fieldbus / network to maximize its flexibility.

Option Installation type
  • RS485 communications card
  • PG interface (5V) card
  • PG interface (12/15V) card
  • Optional control terminal block
  • DeviceNet communication card
  • CC-Link communication card
  • PROFIBUS-DP communication card 
  • EtherNet/IP communication card 
  • ProfiNet-RT communication card 
  • CANopen communication card 
  • Digital input/output interface card
  • Analog input/output interface card
  • Optional front face keypad mount

 

Wide Varity Of Functions As A Standard Feature

  • Sensorless dynamic torque vector control
  • Motor vector control with PG (with optional card)
  • Synchronous motor with sensorless vector control
  • 2-channel on-board RS485 communications port
  • Standard CANopen compatibility
  • Removable keypad device
  • Removable control terminal block board

Multi-Function Keypad(option)

FRENIC-Ace has two different multi-function keypads available

  • Multi-function keypad with LCD display: Enhanced HMI functionality
  • USB keypad: Connect to a computer for more efficient operation (set-up, troubleshooting, maintenance, etc)
  • Multi-function keypad with LCD display USB keypad

Functional Safety

FRENIC-Ace is equipped with STO functional safety function as a standard. Therefore output circuit magnetic contactors are not required for safe stop implementation. Enhanced standard features position FRENIC-Ace ahead of its class (Safety input: 2CH, output: 1CH).

Complies with:

EN ISO 13849-1: 2008, Cat.3 / PL=e IEC/EN 61800-5-2: 2007 SIL3 (Safety feature: STO)
IEC/EN 60204-1: 2005/2006 Stop category 0 IEC/EN 62061: 2005 SIL3
IEC/EN 61508-1 to -7: 2010 SIL3  

 

10 Years Lifetime Design

FRENIC-Ace components have a design life of ten years.
A longer maintenance cycle also helps to reduce running costs.

  Main circuit capacitor 10 years*
Electrolytic capacitors on PCB 10 years*
Cooling fan 10 years*
  Ambient temperature +40°C
Load rate 100% (HHD specifications)
80% (HND/HD/ND specifications)

* ND specifications have a rated current of two sizes higher than HHD specifications, so the life is 7 years.

Standards

RoHS Directive

Standard compliance with European regulations that limit the use of specific hazardous substances (RoHS)

  Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), polybrominated biphenyl ether (PBDE)
  Directive 2002/95/EC, issued by the European Parliament and European Council, limits the use of specific hazardous substances in electrical and electronic devices.

Global compliance

Standard compliance